PV3987高光耐磨測試方法

日期:2023-03-17  1507人瀏覽
放大字體  縮小字體

Scrub Resisitance(Micro-Scrach Resistance)of High-Gloss Surfaces in the Vehicle interrior
 

CRS-RAT往復式磨耗試驗機

Preface
This satandard supersedes the “Audi AG Provisional Test Specification”and Test Specification PV3975(“Matindale Scrub Resistance”)
Previous issues
PV3987:2016-08
Changes
The folloowing changes have been made to PV3987:2016-08
- section 3.1“Test equipment”:exanple changed
1 Scope
This PV describes a method for testing the micro-Scratch resistance and scrub resistance on high-gloss surfaces
A surface is referres to as high-glossy if the gloss level measurement at an angle of 60° is >70GU。Further gloss level measurements are performed with a measuring angle of 20°
 
This test method is suitable for determining the properties of uncoated (Eg PA PMMA)and coat-ed high-gloss surfaces (eg paint ,in-mold decoration(IMD),in-mold labeling(IML))when they are exposed to low-force friction loads。The load is roughly equivalent to that of the cleaning process the test must be performed on plane surfaces
 
The test determines the relative chang in gloss that is generated by rubbing/Scrubbing with polishing paper on the high-gloss surface
 
2 Designation
Scrub resistance (Micro-scratch resistabce)as per PV3987
 
3 Testing
3.1 Test equipment

Test  equipment Crochmeter as per DIN EN ISO105-X12 or a different testing device with which the required test conditions can be set(testing force 9N,Testing path:104±3mm)
Test  head Rubbing adapter C as per DIN55654 (see figure1)
Test equipment/rubbing medium Rolishing paper as per DIN55654:Abrasive grain made of aluminum oxide,semi-open coat density of grain,grain 5um,bonding of grain with full synthetic resin on flexible ,extruded PES film (eg 3M261X)
Cut the polishing paper to an exact width of 25mm and a minimum length of 75mm
Gloss measuring device Measure the gloss level using a reflectometer (as per DIN EN ISO 2813) at angle of 20°

 












 



135681 (Rubber Adapter per DIN55654)2
3.2 Specimen preparation

A minimum Specimen size of 150mmx100mm is required to perfprm the test
Conditioning
There must be at least 7 days between specimen preparation and testing
For conditioning ,plan for 45h in a standard atmosphere as per VW50554-23/50-2 condition hydrophilic materials(eg polyamides)for 7 days in a standard atmosphere
Specimen preparation
Clean the specimen gently under luder lukewarm running water using only your wet hand
 
A mild laboratory flushing agent that does not leave a greasy residue can be used as a cleaning agent
The surfaces to be tested must not be damaged as a result of cleaning
Then rinse the specimen thoroughly with clear water
Dry the specimen by blowing it off with oil-free compressed air
After cleaning,condition hydrophilic materrials once again for 24h in a standard atmosphere

 

3.3 Test procedure
1 condition (see section3.2)
2 clean (see section3.2,for hydrophilic materials ,repeat conditioning if necessary)
3 Meassure the gloss level befor scratching,Measure the gloss level at a measuring angle of 20°
4 Rub/Scratch:Befeor each rubbing process,Clamp in a new rubbing medium。One rubbing
 Process comprise 5 double strokes。Rub with a load of 9N。If the rubbed track is not uniform
(streaky spotted),perform a repeat test
5 After rubbing,store the specimens at room temperature for 24h
6 Measure the gloss level on the track 。Align the gloss measuring device in such a way
 That  themeasuring direction is 90° relative to the rubbing direction。Make sure that the measuring hole of the gloss measuring device rests on the rubbed surface。Do not measure the first and last 10mm of the rubbed track。
 
3.4 evaluation/assessment
Determine the scrub resistance as a relative change in gloss level(%)with respect to the initial
Gloss level。The measuring angle is 20°
Calculate the relative change in gloss level as follow:
(initial gloss level - gloss level after rubbing)x 100 / initial gloss level
 

 

4 Applicable documents
The following documents cited in this standard are necessary to its application
Some of the cited documents are translations from the German original。The translations of German terms in such documents may differ from those used in this stand,resulting in terminologocal inconsistency

 
 
[ 試驗解決方案搜索 ]  [ 加入收藏 ]  [ 告訴好友 ]  [ 打印本文 ]  [ 關閉窗口 ]

本文位置:試驗解決方案
注:蘇州亞諾天下儀器有限公司專業從事試驗室品管檢測設備研發生產!有相對豐富的經驗、有實力強大的團隊、有超強的生產管理能力,選購試驗室檢測設備首選蘇州亞諾天下儀器。我們愿竭誠為您服務+86-512 6855 9199,您的滿意是我最大的追求。
參與評論
©2010-2022 亞諾天下™ 版權所有蘇ICP備11049648號-14 首頁 | 關于我們 | 總經理致辭 | 企業文化 | 服務支援 | 成功案例 | 人才戰略 | 聯系方式 |
 
主站蜘蛛池模板: 91短视频在线观看手机 | 99久久精品国产9999高清 | 天堂中文在线最新版地址 | 熟女丰满老熟女熟妇 | 六月婷婷精品视频在线观看 | 午夜成人看特AAAA片视频 | 超级碰碰碰免费视频 | 午夜影院黄色 | 色哟哟哟在线观看www | 人妻少妇久久中文字幕一区二区 | 538久久视频在线 | 成人在线视频网址 | 无码人妻少妇色欲av一区二区 | 四虎影视在线影院在线观看免费视频 | 极品少妇hdxx麻豆hdxx | 日韩有码在线观看 | 色宅男看片午夜大片免费看 | 免费黄色电影在线观看 | 欧美国产日韩在线 | 亚洲精品鲁一鲁一区二区三区 | a级毛片内射免费视频 | 深夜福利入口 | 搡女人的高清免费视频 | 国产成人一区二区三区别 | 国产成人99精品免费观看 | 国产成人精品三级麻豆 | 亚洲成人黄色在线 | 国产精品福利一区二区 | 六月天色婷婷 | 播放灌醉水嫩大学生国内精品 | 无码精品久久一区二区三区 | 精品午夜久久网成年网 | 米奇7777狠狠狠狠视频影院 | 97se亚洲精品一区 | 亚洲av之男人的天堂 | 亚洲欧美在线观看播放 | 狠狠躁日日躁夜夜躁2022麻豆 | 亚洲免费成人网 | 国产亚洲精品久久久久蜜臀 | 高清国产性色视频在线 | 天天色综合色 |